Note:The following procedure may or may not require the removal of
the inlet and or discharge hose(s) and wiring depending on how
the unit was installed.
Tip:
Operating the unit's dry bowl mode prior to removal, will help
minimize water spillage.
Removal
1.)
To access the integral inlet pump on model A5 and A6. Remove
mounting
fasteners at front of unit.
2.)
Disconnect hoses and wire in rear of unit and noting their position.
3.)
Turn unit upside down on safe surface.
Disconnect
the positive and negative intake pump wires from the fuse block
and
grounding lug.
4.)
Turn unit over and face backside of unit.
Disconnect
hose at pump outlet and hose to pump intake.
Remove
mount support bolts (2)
and carefully remove pump and motor assembly from the rear
of the toilet.