2.)
The CH37E check valve allows a diluted mix of Raritan concentrate
(part #CON) to be drawn up into the rim of the toilet bowl
during flushing.
The
check valve is designed to prevent water from flowing back
and overfilling the CH29A bottle.
If
the concentrate mixture is not being drawn into the bowl or
the
CH29A (tank) is back-filling, the CH37E may need servicing
(cleaning) or replacement.
The
correct location of the CH37E is at the end of the CH37 tubing
and in the bottom of the CH29A
bottle.
|