Page 2 - Crown Head Owners Manual L91v0116v
P. 2

WINTERIZING                        Crown Head units purchased for use with 120/240 volt

            WARNING:  If connected to a Lectra/San or Purasan   AC power will also include a rectified transformer unit
            treatment system there should not be any antifreeze in   (#RTCH24DA), with instructions.
            the system when activating the Lectra/San or Purasan.               INSTALLATION
            Injury to personnel or damage to property could
            result if the Lectra/San or Purasan is activated with   Read This Entire Section Before Beginning     Installation.
            antifreeze in the system.                          Below water line installations must include vented
                                                               loops.  The top of the loop must be above the waterline
            Improper winter lay up is a major cause of marine   at maximum heel to prevent siphoning.  (See FIG 3.)
            toilet failures.
            1.    Close the intake and discharge seacock.  Disconnect   Additional parts required:  Stainless steel fasteners,
                                                               a  single  pole  push  button  switch  (#164000BR)  and  a
               and drain the intake and discharge hoses.  Winterize   continuous duty solenoid (#CDS*) relay or Raritime timer
               seacocks and hoses.                             (#RTC*), 1 1/2” (38 mm) I.D. discharge hose (#SFH)
            2.  You will need two buckets, three feet of 3/4” (19mm)   and  a  reinforced  3/4”  (19mm)  I.D.  intake  hose,  hose
               hose, three feet of 1 1/2” (38mm) hose and a quart   clamps, wire, fuse or circuit breaker (see Crown Head
               (.95 liter) of non-toxic antifreeze.            Specification chart).
            NOTE:  Use only non-toxic antifreeze in this unit.  Mounting the Crown Head:  Be sure Crown Head is on

            3.   Pour about one quart (.95 liter) of non-toxic antifreeze   solid deck construction in a dry location.  Never mount
               into one of the buckets.  Place intake hose in this   the Crown Head where it may be subject to shower
               bucket.  Place empty bucket under discharge hose.    spray or other sources of external water.  Place the
               To ensure antifreeze has circulation through the entire   supplied rubber mounting strips between the base plate
               toilet, flush until antifreeze is discharged.   of the Crown Head and the deck, allowing air to circulate

            4.   Antifreeze  should  remain  in  the  toilet  until   under the motor to prevent moisture from accumulating.
                                                               Use stainless steel fasteners with a minimum size of 1/4”
               recommissioning.  This will protect both intake and   (6 mm).
               discharge sides of the pump.  Pouring antifreeze into
               the bowl will only protect the discharge side of the   1.   Intake Lines:  A 3/4” (19mm) thru-hull fitting and
               pump, allowing the intake side to possibly freeze.     seacock located in an accessible area is required to
                                                                   supply flush water to the bowl.  Connect a 3/4” (19
               NOTE:  Holding  tanks, seacocks  and  treatment     mm) I.D. reinforced suction hose between the seacock
               systems need to be independently winterized,        and intake pump.
               stored and recommissioned (see manufacturer’s
               instructions).                                  NOTE:  An intake In-Line strainer (#163000) is
                                                               recommended to help avoid the accumulation of debris
                         RECOMMISSIONING                       in the intake pump.

            1.  Using the buckets, hoses and a gallon of clean water,   2.  Discharge Lines: Connect quality sanitation rated
               flush  the  antifreeze  out  of  the  toilet.    Dispose  of   1 1/2” (38 mm) I.D. hose (#SFH) to the discharge
               antifreeze  properly, in  accordance  with  local  and   fitting on the toilet and connect to the treatment
               federal regulations.                                system, holding tank, or discharge thru-hull fitting,
            2.   Reconnect the hoses and open both seacocks.       as appropriate.
            3.  Check  all  connections  for  leaks  with  several  test  TIP:  To retain water in the bowl install a vented loop
               flushes.                                        in the discharge line.
                        SYSTEM COMPONENTS
            Before starting installation please be sure that all parts
            that were ordered with your model have been included:   Allow sufficient space at the side and rear to connect
            The complete Crown Head unit includes:  bowl, seat and  hoses.  If space is limited, the bowl can be rotated 90
            cover, motor assembly, shroud assembly, siphon and check  degrees (a longer hose [#CH42] is required, contact
            valve assembly, Concentrate tank, 2 oz. (59ml) of C.P.,  Raritan Technical Support).
            two mounting strips and an owner’s manual.


                         * Specify Voltage                    2                                         L91  0116jlc
   1   2   3   4   5   6   7