Page 3 - Raritan Momentary Control Owners Manual L483-v0216
P. 3
WIRING 2. Select proper wire and fuse/circuit breaker
WARNING: Hazard of Shock and Fire size from Specifications on specification
• Always use proper wire, wire connectors page.
and fuse/circuit breaker. See Specification 3. Install fuse/circuit breaker in positive line
Chart. at source. WIRING
• Secure wire properly. 4. Wire control to the toilet and battery using
• Do not connect appliances to toilet circuit. one of the following wiring diagrams.
• Make sure power is off before proceeding. MSD OPERATION
• Use proper wire terminals for all wire
connections. To start Electroscan from toilet control, run
1. Determine proper wire size by measuring a wire from “to MSD “ to terminal marked
“EXT TRIG” inside Electroscan control mod-
distance from: ule (black box).
• Power Source to push button to toilet To start toilet equipped with Smart toilet
motor and back to power source. control from Electroscan, connect “Head1” to
• Remote pump units - also include “FROM MSD “.
distance from power source for remote For Lectra/San MC, EC call Raritan Customer
pump to remote pump and back. Same Service
wire gauge must be used for both
discharge and remote pump.
Fig. 2 WIRING FOR MULTIFUNCTION MOMENTARY CONTROL,
FRESHWATER MODEL
FUSE/
CIRCUIT BREAKER
221551
SEE
RECOMMENDED
BATT + IN PUMP / VALVE + IN PUMP / VALVE - SF IN VALVE + SF IN VALVE - FILL/EMPTY SWITCH SEA/FRESH SWITCH BATT - BATTERY
WIRE SIZE
DISCH + DISCH - TO MSD R B W R B W
SEE
RECOMMENDED
WIRE SIZE
GRAY
CABLE FILL/EMPTY SWITCH
RED FILL 2 1
(12AWG) WHITE
FILL
DISCHARGE BLACK
PUMP (12AWG) EMPTY FLUSH
BLACK EMPTY
BLUE
(16AWG) 4 3
WATER BLACK IN+
VALVE (16AWG) RED
WIRE
JUMPER
L483 0216jlc 3