Short Term Storage - longer than 2 weeks.  (for up to
        2 weeks of non-use, system may be left as-is)

        1.  Flush toilet system with fresh water.


        2.  Leave aerator pump running.


        3.  Once a week, flush five gallons of water into  system.
        Important:  Failure to follow this procedure may cause
        the system to go septic (anaerobic), creating foul odors.


        Winterizing/Dry Storage (long term storage - more
        than 2 months)

        1.  Flush toilet several times to clear any waste from lines.


        2. Shut off any valves between toilet and   ManaGerM.

        3.  Pump out system.  Rinse both tanks until only clear                                                STORAGE AND WINTERIZING
             water is being pumped out.


        4.  Turn off power (unplug) to aeration pump.




        START UP


        1.  Unscrew Dispenser lid, then fill tablet dispenser with
            tablets (stack 2 tablets flat inside dispenser) - top
            figure on right.

        2.  Remove large inspection lid (64102) and fill system
            with water until it is being discharged from system.
            Replace large inspection lid (64102) - center figure
            on right.

        3.  Add 1 ½ oz (42.5 grams) of startup enzyme (½ bottle)
            to one gallon (3.785 LITERS) of cold or lukewarm
            water - bottom figure on right.

        CAUTION:  Hot water above 120° F. (49° C.) will
                            destroy bacteria.


        4.  Flush solution down toilet into system.

        5.  Turn on aerator pump.