PHII AND PHEII MARINE TOILETS


                           INSTALLATION AND MAINTENANCE INSTRUCTIONS


           THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND
           FOLLOWED DURING BOTH INSTALLATION AND OPERATION
           WARNING:  Raritan Engineering Company, Inc. recommends that a qualified  person or electrician in the case
                       of  PHEII,  install this product.  Equipment damage, injury to personnel or death could result
                       from improper installation.  Raritan Engineering Company,  Inc.  accepts no responsibility or li-
                       ability for  damage to equipment, or injury or death to personnel,  that may result from improper
                       installation or operation of this product.
           WARNING:  Hazard of Flooding - Any installation made below the waterline must have vented loops posi-
                       tioned properly and all hose connections should be double-clamped.  Both intake and discharge
                       seacocks should always be in the closed position when the toilet is not in use.  Failure to do so
                       may result in flooding, property damage and loss of life.
           WARNING:  Hazard of Fire - Do not wire 120V PHEII motors without using specified rectifier.
                       Do not operate PHEII series toilets with handle in place, serious bodily injury may occur.
























               The PHII is a manually operated double ac-       The PHEII is the electric version which
               tion piston toilet. The PHII can be converted    incorporates an electric motor driven gear
               to its electrical counterpart by adding an       box.
               electrical conversion kit part# PHECKII*.

                                                              All models are suitable for use in conjunction
                                                              with Raritan’s Electroscan® and Purasan®.

          Model and Serial # for PHEII:                       Both are US Coast Guard Certified Type I flow-
                                                              thru Marine Sanitation Device (MSD) and/or
                                                              holding tanks.












                                                                             1-856-825-4900
                                                                           www.raritaneng.com
           L04v0320jlc                                        1