Page 3 - Raritan Macerator Pump Owners Manual L552-0619
P. 3

PLUMBING

          Plumbing Connections
                                                                  FIG 1
          Pump should be mounted as near as possible to tank to               Installing on threaded flange
          minimize dry run.  Pump is self-priming to a five-foot
          lift when impeller is wet, four foot lift when impel-
          ler is dry.  Pump is more efficient if mounted near the
          holding tank.
          INLET:  For model 53100; Always install pump with
          a shut-off valve between pump and holding tank.
          Model 53101 includes an integral wastewater valve.                                                      INSTALLATION
          HOSE: Use 1-1/2” ID [non-collapsible vacuum rated]
          hose on inlet [suction] side.  Use stainless steel hose   FIG 2
          clamps on all sanitation connections.
          FLANGE: For model 53100: To mount to 1-1/2”
          female flange, inlet barb must be cut off just before
          threads.  Seal threads and hand tighten. For model
          53101: Use 1 1/2" threaded nipple between  FPT
          flange and waste valve . Use thread sealant to tighten
          joints.
          WARNING:   Any air leak on inlet side can cause
          pump to run dry and can damage impeller and impel-
          ler housing.  Check all inlet side connections, even
          those on deck plates.  All runs should be smooth with
          no kinks or sharp angles.
          OUTLET:  Use 1” minimum ID hose on discharge
          side of pump. Install a 1" shut-off valve   between
          pump quick disconnect and hose. Connect to thru-hull                      Quick disconnect
          fitting above highest heeled point above waterline.
          Vented loop installations must vent above highest       FIG 3
          heeled point above waterline (see WARNING below).                Optional Valve
          Use stainless steel hose clamps on all sanitation con-
          nections.






        WARNING: HAZARD  OF FLOODING
        •  Installations at or below waterline, at   FIG 4       Below waterline installation
          greatest angle of heel, MUST have a
          VENTED LOOP installed between the
          Pump’s Discharge and Seacock/Thru                                   Vented loop           10" above
          Hull  Fitting. Install  vented  loop  per                                                 max heeled
          manufacturer's instructions.                                                              water line
        •  Double clamp all below waterline hose
          connections.









                 L552 0619jlc                                                                                       3
                                                              3