Page 4 - Raritan Macerator Pump Owners Manual L552-0619
P. 4
WIRING
INSTALLATION
WARNING: Hazard of Shock and Fire FIG 5 Wiring with on-off switch
• Always use proper wire, wire connectors
and fuse/circuit breaker. See Specification Orange/Red Black
Chart. -
• Secure wire properly. +
• Do not connect other equipment to PUMP
macerator circuit.
• Make sure power is off before proceeding.
• Use proper wire terminals if needed for all
F
wire connections. Switch Fuse/Circuituse/Circuit BATT
Br
1. Determine proper wire size by measuring Breakereaker
distance from:
• Power Source to switch to pump motor and
back to power source. FIG 6 Wiring with
• For models with Smart Macerator Control, Smart Macerator Control
include distance from power source to SMC
controller to pump and back. BATT + BATT - PUMP+ PUMP- SW/LED+ Smart Macerator Control
RARITAN
2. Select proper wire and fuse/circuit breaker SW- LED-
size from Specifications on Installation page.
3. Install fuse/circuit breaker in positive line at 16 AWG
source.
Orange
Wiring with ON_OFF switch (FIG 5): Black
NOTE: Switch is not included. Mount switch
near macerator pump so that operator can hear Fuse/Circuit ESR03A
change in pump sound when tank is empty. If Breaker
mounting in area where ignition protection is
required use only ignition protected switch.
4. Wire as per Fig 5.
Wiring with Optional Smart Macerator Control
(FIG 6):
FIG 7 Switch (ESR03A)
NOTE: Switch (ESR03A) included with SMC, CUTOUT 0.756 (19.2) x 0.512(13)
should only be installed in area not requiring
ignition protection. Wires needed between
switch and control are not included (FIG 7) WIRING DIAGRAM
+
5. Wire as per FIG 6. 1 2
-
NOTE: Reverse polarity will run pump as soon 0.920 0.925
as power is turned on even if switch is not on. [23.4] [23.5]
Power must be turned off immediately (within MOUNTING HOLE: DIA .795 [20.2]
2 minutes) and polarity should be corrected to MAXIMUM PANEL THK: .250 [6]
avoid permanent damage to the control. INCH [MM]
4 4 L552 0619jlc