SPECIFICATIONS
CONVERSIONS
Wire - AWG to mm 2
AWG 16 14 12 10 8 6 4 2
mm 2 1.5 2.5 4.0 6.0 10.0 16.0 25.0 35.0
Feet to Meters
10 15 20 25 30 40 50
Feet
Meter 3.1 4.6 6.1 7.6 9.2 12.2 15.2
Plumbing
Maximum suction of Intake pump 4 Ft. (1.2m) from Intake Pump.
(Maximum height above waterline)
6 Ft. (1.8m) from base of toilet.
Maximum height of discharge vented loop
Minimum flow rate of 3 gpm (11.3 liters).
Pressurized water source requirements Minimum pressure of 5 psi (34.5 kPa).
NOTES: for Wiring
1. Distances are from source to unit and back to source.
2. Distance from power source to remote intake pump MUST be included when
determining total distance.Same wire size MUST be used for lower base and
remote intake pump.
3. Recommended conductor wire minimum AWG (mm 2) for 3% voltage drop.
4. Recommended conductor sizes are based on 105 oC rated insulation.
Refer to ABYC Standards for other insulation ratings.
5. For 120/240 VAC units, use 12VDC specifications from transformer to unit.
Sea Water Model - Recommended Wire and Fuse/Circuit Breaker Size
Integral Pump and lower
Circuit base
Units Breaker/ 15 20 30 40 50
Voltage fuse size Amp. draw feet feet feet feet feet
(amps) @ nominal voltage
12 VDC 25 18 10 AWG 8 AWG 6 AWG 6 AWG 4 AWG
24 VDC 15 10 14 AWG 14 AWG 12 AWG 10 AWG 10 AWG
32 VDC 15 7.5 14 AWG 14 AWG 14 AWG 12 AWG 12 AWG
4 L318 v1215jlc