Page 4 - Raritan SeaEra Owners Manual L318v1215
P. 4

SPECIFICATIONS
                                                                                   CONVERSIONS
                                                                                     Wire - AWG to mm 2

                                                                         AWG   16  14   12  10   8    6    4   2


                                                                         mm 2  1.5  2.5  4.0  6.0  10.0  16.0  25.0  35.0


                                                                                      Feet to Meters
                                                                                        10  15  20  25  30  40  50
                                                                         Feet

                                                                         Meter 3.1  4.6  6.1   7.6  9.2  12.2  15.2


             Plumbing
              Maximum suction of Intake pump  4 Ft. (1.2m) from Intake Pump.
              (Maximum height above waterline)

                                                                                               6 Ft. (1.8m) from base of toilet.
              Maximum height of discharge vented loop

                                                                                            Minimum flow rate of 3 gpm (11.3 liters).
              Pressurized water source requirements  Minimum pressure of 5 psi (34.5 kPa).


              NOTES: for Wiring

               1. Distances are from source to unit and back to source.

              2.  Distance from power source to remote intake pump MUST be included when
                  determining total distance.Same wire size MUST be used for lower base and
                  remote intake pump.
              3.  Recommended conductor wire minimum AWG (mm 2) for 3% voltage drop.

              4.  Recommended conductor sizes are based on 105 oC rated insulation.
                  Refer to ABYC Standards for other insulation ratings.

              5.  For 120/240 VAC units, use 12VDC specifications from transformer to unit.


             Sea Water Model - Recommended Wire and Fuse/Circuit Breaker Size

                                     Integral Pump and lower
                           Circuit          base
                 Units    Breaker/                            15         20         30         40         50
                Voltage   fuse size      Amp. draw            feet       feet       feet       feet      feet
                           (amps)      @ nominal voltage


                12 VDC      25               18            10 AWG      8 AWG      6 AWG      6 AWG      4 AWG
                24 VDC      15               10            14 AWG      14 AWG     12 AWG    10 AWG     10 AWG
                32 VDC      15               7.5           14 AWG      14 AWG     14 AWG    12 AWG     12 AWG




                                                                4                                         L318 v1215jlc