Page 8 - Raritan Hold-N-Treat for Purasan EX L519v0919
P. 8
INSTALLATION
C. Treatment Unit:
PLUMBING NOTE: Use PTFE tape or nonpermanent thread
WARNING: HAZARD OF FLOODING sealing compound on threaded PVC fittings and
• Installations at or below waterline, at greatest connections. Avoid low areas in hose that would
angle of heel, MUST have a VENTED LOOP allow untreated waste to collect.
installed between Treatment Tank and Seacock/ 1. Connect discharge of macerator to one intake
Thru Hull Fitting. Install vented loops per port.
manufacturer’s instructions. 2. Insert plug or second toilet discharge into
• Double clamp all below waterline hose other intake port.
connections. 3. Determine position and glue discharge elbow
Use only non-corrosive fittings to top of tank using PVC cement.
A. Macerator pump: Note: Be certain that the discharge
1. Install macerator pump between holding tank and elbow is in the correct position before gluing.
treatment system. 4. Connect discharge hose from elbow to thru
B. Pressurized water for Tablet Dispenser: hull fitting.
1. Connect hoses from control module to treat- Fittings for winterization:
ment tank and tablet dispenser as per FIG 8 It is recommended that T- fitting with a shut of
2. A shutoff valve between source and Water valve or plug should be installed near intake
Valve assembly is recommended. port of the treatment unit or lowest part of
3. Use hose clamps to secure hoses the plumbing for draining or flushing system
during winterization
FIG 8 Plumbing: Pressurized fresh water to Dispenser
TABLET
DISPENSER
1/4"
TUBING
PRESSURIZED
FRESH WATER SOURCE
WITH SHUT OFF VALVE
3/8"
TUBING
VENTED LOOP VENTED LOOP
MACERATOR
PUMP CHECK
VALVE
FROM TUBING
TOILET
CLAMP
HOLDING
TANK 1 1/2"
HOSE
8 L519 _0919jlc