INSTALLATION
                                                                  C. Treatment Unit:
                               PLUMBING                          NOTE: Use PTFE tape or nonpermanent thread
            WARNING: HAZARD OF FLOODING                            sealing compound on threaded PVC fittings and
            •  Installations at or below waterline, at greatest    connections. Avoid low areas in hose that would
              angle of heel, MUST have a VENTED LOOP               allow untreated waste to collect.
              installed between Treatment Tank and Seacock/        1.   Connect discharge of macerator to one intake
              Thru Hull Fitting. Install vented loops per             port.
              manufacturer’s instructions.                         2.   Insert plug or second toilet discharge into
            •  Double  clamp  all  below  waterline  hose             other intake port.
              connections.                                         3.   Determine position and glue discharge elbow
              Use only non-corrosive fittings                         to top of tank using PVC cement.
            A. Macerator pump:                                     Note:  Be certain that the discharge
             1. Install macerator pump between holding tank and    elbow is in the correct position before gluing.
              treatment system.                                    4.   Connect discharge hose from  elbow to thru
              B. Pressurized water for Tablet Dispenser:              hull fitting.
              1. Connect hoses from control module to  treat-      Fittings for winterization:
                 ment tank and tablet dispenser as per FIG 8           It is recommended that T- fitting with a shut of
              2. A shutoff valve between source and Water             valve or plug  should be installed near intake
                 Valve assembly is recommended.                       port of the treatment unit or lowest part of
              3.  Use hose clamps to secure hoses                     the plumbing for draining or flushing system
                                                                      during winterization




                FIG 8    Plumbing: Pressurized fresh water to Dispenser

                                                                                  TABLET
                                                                                 DISPENSER


                                                                            1/4"
                                                                          TUBING




                                         PRESSURIZED
                                     FRESH WATER SOURCE
                                     WITH SHUT OFF VALVE
                                                                               3/8"
                                                                             TUBING

                                            VENTED LOOP                         VENTED LOOP
                                  MACERATOR
                                     PUMP                                   CHECK
                                                                            VALVE
                          FROM                                              TUBING
                         TOILET
                                                                            CLAMP

                                   HOLDING
                                    TANK                                                 1 1/2"
                                                                                         HOSE